Andy:

I don't have the System Handbook at hand, but the 7600 seems to be the
internal disks, so a couple of things I would do:
a) check in the wrkdsksts the status of the unit
b) if you are in V3R1 or later do a WRKHDWRSC *STG to find the serial number
of the disk.
or
c) do an STRSST option 3 Wrk with dsk units / option 1 Dsp dsk
configuration/option 1 Dsp dsk configuration status / F9 dsp details.
These are the option in a RISC machine, may be they are different in a CISC
one but this is the general idea ).

Just a doubt: are you going to replace it by yourself? If not, then the IBM
CE would handle all the burden.

hth

Guillermo

PS: Do you have a SAVSYS?


-----Original Message-----
IGNITE400 MEMBERS LIST
To: IGNITE400 MEMBERS LIST Mailing List
Date: Saturday, October 03, 1998 11:56 AM
problem IPL Drives


>From: Asugclevel@aol.com
>
>Howdy ;-)))
>
>Let see how ignite 400 works.. I have IPL drives model 7600 old ones, on
my
>B50 also old. The AS/400 has told me that unit 11 is down (I have
morroring).
>How do I find where unit 11 is. I know they are old and IPL was sold
several
>times but I still have the problem. Any help, phone number what ever
would
>be helpful
>Thank you
>
>Andy Gladys
>Cleveland Ohio USA
>
>--- IGNITE400 MEMBERS LIST
>What AS/400 IP services do you run?
>
>http://ignite400.org/member/html/survey.htm
>
>